Customization: | Available |
---|---|
Type: | Central Air Conditioners |
Capacity: | 18000-24000 BTU |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model No. | Indoor unit | EKCK030A | EKCK050A | |||
Outdoor unit | EKAA030AK | EKAA030ARK | EKAA050AK | EKAA050ARK | ||
Nominal Cooling Capacity | W | 7800 | 7800 | 12500 | 12500 | |
Nominal Heating Capacity | W | .-- | 8000 | .-- | 15000 | |
Rated input power | Cooling | W | 2550 | 2600 | 4300 | 4300 |
Heating | W | .-- | 2500 | .-- | 5100 | |
Rated current | Cooling | A | 12 | 12 | 7.6 | 7.6 |
Heating | A | .-- | 11.5 | .-- | 9.1 | |
EER | W/W | 2.82 | 2.77 | 2.79 | 2.79 | |
Energy Efficiency Rating | 3 | 4 | 4 | 4 | ||
Indoor unit | Air flow | m³/h | 1200 | 1200 | 1700 | 1700 |
Power | W | 127 | 186 | |||
Current | A | 0.58 | 0.86 | |||
Noise | dB(A) | 40 | 44 | |||
Main unit (L * W*H) | mm | 705*705*290 | 832*832*290 | |||
Panel (L * W*H) | mm | 830*830*30 | 980*980*30 | |||
Weight | kg | 31 | 41 | |||
Outdoor unit | Noise | dB(A) | 59 | 61 | ||
Weight | kg | 55 | 56 | 105 | 112 | |
L * W*H | mm | 840*311*697 | 970*345*1255 | |||
Power supply | 220v /50hz | 380v/50hz | ||||
Connector size | External diameter of liquid tube | mm(in.) | 9.52 (3/8) | |||
External diameter of air tube | mm(in.) | 15.88 (5/8) | 19.05 (3/4) | |||
Pipe connection mode | The copper tube tulip opening is connected to the threading connector | |||||
Water drainage pipe | diameter 27mm | |||||
Note: 1. The GB 19576-2004 EER standard is applied. 2. The nominal cooling capacity is measured under the following conditions: The indoor dry/wet bulb reads 27/19 °C and the outdoor dry/wet bulb reads 35/24 °C. 3. The nominal heating capacity is measured under the following conditions: The indoor dry/wet bulb reads 20/15 °C and the outdoor dry/wet bulb reads 7/6 °C. 4. The sound pressure level noise is measured through test in a semi-anechoic room. Due to environment noise and other factors in actual operation, the actual noise may be different from those listed in the preceding table. 5. The preceding data shows parameters when the horizontal length of connecting pipes between indoor and outdoor units is 5 m. 6. For details about on-site power distribution and wiring for unit installation, see the nameplate or installation manual of the unit. |
||||||
Electric parameter | ||||||
Model | Indoor unit | EKCK030A | EKCK050A | |||
Outdoor unit | EKAA030AK | EKAA030ARK | EKAA050AK | EKAA050ARK | ||
Power supply | 220v/50hz | 380v/50hz | ||||
Power cable | Cross sectional area (mm²) | 4 | 4 | 4 | 4 | |
Number | 3 | 3 | 5 | 5 | ||
Cables connecting indoor unit and outdoor unit | Cross sectional area (mm²) | 2.5 | 2.5 | 2.5 | 2.5 | |
Number | 5 | 6 | 5 | 6 | ||
Fault reporting cables between indoor and outdoor units | Cross sectional area (mm²) | 1.5 | 1.5 | 1.5 | 1.5 | |
Number | 3 | 3 | 3 | 3 | ||
Note: 1. The preceding cable specifications are recommended. 2. All wires must be well connected. Connecting wires must be fixed by wire clips. 3. All wires must avoid refrigerant pipeline and movable parts such as compressor and fan motor. 4. Connecting wires must adopt chloroprene rubber copper conductor cables. The cross sectional area must meet the requirements listed on the preceding table. 5. A circuit breaker with sufficient capacity must be set at the power input wire. The breaker has a contact separation of at least 3 mm. 6. For details about on-site power distribution and wiring for unit installation, see the nameplate or installation manual of the unit. |