Environmental Friendly Air Cooled Water Chiller R410A

Type: Air-Cooled
Cooling Method: Air-cooled
Certification: ISO
Condition: New
Transport Package: Standard Exporting Package
Trademark: tili
Customization:
Diamond Member Since 2011

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company

Basic Info.

Model NO.
EKAC220BR1
Origin
Guangdong Province
HS Code
8418619000
Production Capacity
10000 Unit/Year

Product Description

The modular air-cooled water chiller with environment friendly refrigerant model uses new-generation R410A refrigerant which does not cause ozone depletion. The unit features optimized system design and an excellent COP. The unit is not only cost effective but also environment friendly, easy to operate, reliable in performance, and can be installed flexibly. Therefore, units of this series are widely used in dining halls, bars, hotels, offices, top-tier clubs, hospitals, etc.

Environmental Friendly Air Cooled Water Chiller R410A
 
Environmental Friendly Air Cooled Water Chiller R410AEnvironmental Friendly Air Cooled Water Chiller R410A
Model No.   EKAC220BR1 EKAC440BR1 EKAC660BR1 EKAC880BR1 EKAC1100BR1 EKAC1320BR1
Nominal cooling capacity kw 63 126 189 252 315 378
Nominal heating capacity kw 68 136 204 272 340 408
Total power of nominal cooling capacity kw 19 38 57 76 95 114
Total power of nominal heating capacity kw 19.8 39.6 59.4 79.2 99 118.8
Power supply v/ph/hz 380/3/50
Flow control   Electronic expansion valve
Refrigerant   R410A
Compressor Qty Set 2 4 6 8 10 12
Water side heat  exchanger Type   High-efficiency  vacuum braze-welded panel type
Water flow for cooling m³/h 10.8 21.6 32.4 43.2 54 64.8
Water flow rate in heating mode m³/h 11.7 23.4 35.1 46.8 58.5 70.2
Fan Qty Set 2 4 6 8 10 12
Water resistance kPa 43 43 43 43 43 43
Recommended diameter for water pipes inch ≥2 ≥3 ≥3 ≥4 ≥4 ≥5
Dimensions L×H mm  2012×1840
Width mm  880 2125 3370 4615 5860 7105
Net weight kg 515 1030 1545 2060 2575 3090
Operation weight kg 525 1050 1575 2100 2625 3150
Note:
1. Test conditions for nominal cooling capacity: outlet water temperature 7°C; water flow: 0.172m3/(h@kw); outdoor ambient temperature 35°C.
2. Test conditions for nominal heating capacity: outlet water temperature 45°C; water flow: 0.172m3/(h@kW); outdoor dry/web bulb temperature 7°C/6°C.
3. Water resistance at the air conditioner side includes water pressure drop of the unit and the attached Y-shaped filter.
4. Main Pipes of combined units need to be customized and installed on site. The diameter of the pipes must meet design requirements. TILI does not provide the pipes.
5. Modular units can be formed using the 1 - 16 basic modules of same type or of different types as per practical needs. The above table lists the parameters for common module combinations.
6. For on-site electric wiring, see the name plate or installation menu of the unit.