• Air Cooled Water Chiller with Heat Recovery
  • Air Cooled Water Chiller with Heat Recovery
  • Air Cooled Water Chiller with Heat Recovery
  • Air Cooled Water Chiller with Heat Recovery

Air Cooled Water Chiller with Heat Recovery

Type: Air-Cooled
Cooling Method: Air-cooled
Unit Structure: Integral
Selected Voltage: 380V/50HZ
Compressor Number: 1
Noise Level: Low
Customization:
Diamond Member Since 2011

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company

Basic Info.

Certification
ISO, CE, CCC
Condition
New
Usage
Heating/Cooling + Hot Water
Transport Package
Standard Exporting Package
Trademark
Tili
Origin
Guangdong Province
HS Code
8418619000
Production Capacity
10000 Unit/Year

Product Description

1) Saving energy:COP up to 8.32
2) Operating range : -10 to 48 degree
3) Noise level low to 54dB(A)
4) Smart control based on module combination
5) High efficiency H.E.
6) Air Cooled absorption chiller with Heat Recovery

Air Cooled Water Chiller with Heat Recovery

i) Installation:

Air Cooled Water Chiller with Heat Recovery


ii) Inner system:
Air Cooled Water Chiller with Heat Recovery
Model No.
EKAC230BRSR EKAC460BRSR EKAC690BRSR EKAC920BRSR EKAC1150BRSR EKAC1380BRSR
Air conditioning mode Nominal cooling capacity kw 65.5 131 196.5 262 327.5 393
Nominal heating capacity kw 69 138 207 276 345 414
 Nominal cooling input power kw 19.4 38.8 58.2 77.6 97 116.4
 Nominal heating input power kw 19.2 38.5 57.7 76.9 96.2 115.4
Water flow rate for nominal cooling capacity m3/h 11.3 22.5 33.8 45.1 56.3 67.6
Water flow rate for nominal heating capacity m3/h 11.9 23.7 35.6 47.5 59.3 71.2
Hot water mode Nominal water supply capacity kw 16.3 32.7 49 65.4 81.7 98
Nominal heating capacity kw 76 152 228 304 380 456
Total power of nominal heating capacity kw 18.4 36.7 55.1 73.5 91.8 110.2
Cooling + heat recovery mode Nominal cooling capacity kw 59.7 119.4 179.1 238.8 298.5 358.2
Nominal heat recovery capacity kw 76 152 228 304 380 456
Nominal input power kw 16.3 32.6 48.9 65.2 81.5 97.8
Nominal water supply capacity at heat recovery side m3/h 16.3 32.6 48.9 65.2 81.5 97.8
Nominal water flow at
evaporator side
m3/h 10.3 20.5 30.8 41.1 51.3 61.6
Power supply v/ph/hz 380/3/50
Flow control
Electronic expansion valve
Refrigerant
R22
Heat  exchanger type Air conditioning side m³/h braze-welded panel-type heat exchanger
hot water side m³/h High-efficiency bucket heat exchanger
Compressor Qty Set 2 4 6 8 10 12
Fan Qty Set 2 4 6 8 10 12
Water
resistance
Air conditioning side kPa 45 45 45 45 45 45
hot water side kPa 75 75 75 75 75 75
Minimum
diameter for
water pipes
Air conditioning side inch ≥2 ≥3 ≥3 ≥4 ≥4 ≥5
hot water side inch ≥2 ≥3 ≥4 ≥4 ≥5 ≥5
Dimensions L×H mm  2012×1840
Width mm  880 2125 3370 4615 5860 7105
Power cable specification Section area of live line mm² ≥10 ≥35 ≥70 ≥95 ≥120 ≥150
Qty.of live lines
3
Section area of null line mm² ≥4
Qty.of live lines
1
Section area of grounding line mm² ≥10 ≥16 ≥35 ≥50 ≥60 ≥75
Qty.of grounding lines
1
Net weight kg 600 1200 1800 2400 3000 3600
Operation weight kg 620 1240 1860 2480 3100 3720
Note:
1. Air conditioning mode: Test conditions for nominal cooling capacity: outlet water temperature 7°C; water flow: 0.172 m3/(h@kW); outdoor ambient temperature
35°C. Test conditions for nominal heating capacity: outlet water temperature: 45°C; water flow: 0.172 m3/(h@kW); temperature of outdoor dry/wet bulb: 7°C/6°C.
2. Cooling + Heat recovery mode Test conditions for nominal cooling capacity: Hot water side: temperature of outlet water 45°C, water flow 0.215 m3/(h@kW); Air
conditioning side: temperature of outlet water 7°C, water flow 0.172 m3/(h@kW);
3. Hot water mode: Test conditions for nominal water flow: Ambient temp: 20/15°C; outlet water temp: 45°C; water flow of cooling + heat recovery mode.
4. Water resistance at the air conditioner side includes water pressure drop of the unit and the attached Y-shaped filter.
5. Water resistance at the hot water side includes water pressure drop of the unit and does not include the pressure drop at the Y-shaped filter and other
components.
6. Pipes outside the unit need to be customized and installed on site. The diameter of the pipes must meet design requirements. TILI does not provide the pipes.
7. Full heat recovery units and other units can be combined to form partial heat recovery modular system. Full heat recovery units can also be combined to form a
total heat recovery system. Modular units can be formed using the 1~16 basic modules. The above table lists the parameters for common module combinations.
8. For on-site electric wiring, see the name plate or installation menu of the unit.