Home
Product Directory
Industrial Equipment & Components
Refrigeration Equipment
Industrial Chiller
Refrigeration Chiller
Air Cooled Water Chiller with Heat Recovery
Negotiable | 1 Set (MOQ) |
Min. Order:
1 Set
Production Capacity:
10000 Unit/Year
Transport Package:
Standard Exporting Package
Payment Terms:
L/C, T/T, Western Union
Guangdong Tili Refrigeration Equipment Co., Ltd.
Guangdong, China
Last Login Date:
Aug 19, 2025
Main Products:
Heat Pump, Water Source Heat Pump, Swimming Pool Heat Pump, Compressor, Air Conditioner, Air Source Heat Pump, Water Heater, Chiller, Dehumidifier, Refrigerant
Find Similar Products
Product Description
Company Info
Basic Info.
Type
Air-Cooled
Cooling Method
Air-cooled
Unit Structure
Integral
Selected Voltage
380V/50HZ
Compressor Number
1
Noise Level
Low
Certification
ISO, CE, CCC
Condition
New
Usage
Heating/Cooling + Hot Water
Trademark
Tili
Origin
Guangdong Province
HS Code
8418619000
Product Description
2) Operating range : -10 to 48 degree
3) Noise level low to 54dB(A)
4) Smart control based on module combination
5) High efficiency H.E.
6) Air Cooled absorption chiller with Heat Recovery
i) Installation:
ii) Inner system:
Model No. | EKAC230BRSR | EKAC460BRSR | EKAC690BRSR | EKAC920BRSR | EKAC1150BRSR | EKAC1380BRSR | ||
Air conditioning mode | Nominal cooling capacity | kw | 65.5 | 131 | 196.5 | 262 | 327.5 | 393 |
Nominal heating capacity | kw | 69 | 138 | 207 | 276 | 345 | 414 | |
Nominal cooling input power | kw | 19.4 | 38.8 | 58.2 | 77.6 | 97 | 116.4 | |
Nominal heating input power | kw | 19.2 | 38.5 | 57.7 | 76.9 | 96.2 | 115.4 | |
Water flow rate for nominal cooling capacity | m3/h | 11.3 | 22.5 | 33.8 | 45.1 | 56.3 | 67.6 | |
Water flow rate for nominal heating capacity | m3/h | 11.9 | 23.7 | 35.6 | 47.5 | 59.3 | 71.2 | |
Hot water mode | Nominal water supply capacity | kw | 16.3 | 32.7 | 49 | 65.4 | 81.7 | 98 |
Nominal heating capacity | kw | 76 | 152 | 228 | 304 | 380 | 456 | |
Total power of nominal heating capacity | kw | 18.4 | 36.7 | 55.1 | 73.5 | 91.8 | 110.2 | |
Cooling + heat recovery mode | Nominal cooling capacity | kw | 59.7 | 119.4 | 179.1 | 238.8 | 298.5 | 358.2 |
Nominal heat recovery capacity | kw | 76 | 152 | 228 | 304 | 380 | 456 | |
Nominal input power | kw | 16.3 | 32.6 | 48.9 | 65.2 | 81.5 | 97.8 | |
Nominal water supply capacity at heat recovery side | m3/h | 16.3 | 32.6 | 48.9 | 65.2 | 81.5 | 97.8 | |
Nominal water flow at evaporator side | m3/h | 10.3 | 20.5 | 30.8 | 41.1 | 51.3 | 61.6 | |
Power supply | v/ph/hz | 380/3/50 | ||||||
Flow control | Electronic expansion valve | |||||||
Refrigerant | R22 | |||||||
Heat exchanger type | Air conditioning side | m³/h | braze-welded panel-type heat exchanger | |||||
hot water side | m³/h | High-efficiency bucket heat exchanger | ||||||
Compressor | Qty | Set | 2 | 4 | 6 | 8 | 10 | 12 |
Fan | Qty | Set | 2 | 4 | 6 | 8 | 10 | 12 |
Water resistance | Air conditioning side | kPa | 45 | 45 | 45 | 45 | 45 | 45 |
hot water side | kPa | 75 | 75 | 75 | 75 | 75 | 75 | |
Minimum diameter for water pipes | Air conditioning side | inch | ≥2 | ≥3 | ≥3 | ≥4 | ≥4 | ≥5 |
hot water side | inch | ≥2 | ≥3 | ≥4 | ≥4 | ≥5 | ≥5 | |
Dimensions | L×H | mm | 2012×1840 | |||||
Width | mm | 880 | 2125 | 3370 | 4615 | 5860 | 7105 | |
Power cable specification | Section area of live line | mm² | ≥10 | ≥35 | ≥70 | ≥95 | ≥120 | ≥150 |
Qty.of live lines | 3 | |||||||
Section area of null line | mm² | ≥4 | ||||||
Qty.of live lines | 1 | |||||||
Section area of grounding line | mm² | ≥10 | ≥16 | ≥35 | ≥50 | ≥60 | ≥75 | |
Qty.of grounding lines | 1 | |||||||
Net weight | kg | 600 | 1200 | 1800 | 2400 | 3000 | 3600 | |
Operation weight | kg | 620 | 1240 | 1860 | 2480 | 3100 | 3720 | |
Note: 1. Air conditioning mode: Test conditions for nominal cooling capacity: outlet water temperature 7°C; water flow: 0.172 m3/(h@kW); outdoor ambient temperature 35°C. Test conditions for nominal heating capacity: outlet water temperature: 45°C; water flow: 0.172 m3/(h@kW); temperature of outdoor dry/wet bulb: 7°C/6°C. 2. Cooling + Heat recovery mode Test conditions for nominal cooling capacity: Hot water side: temperature of outlet water 45°C, water flow 0.215 m3/(h@kW); Air conditioning side: temperature of outlet water 7°C, water flow 0.172 m3/(h@kW); 3. Hot water mode: Test conditions for nominal water flow: Ambient temp: 20/15°C; outlet water temp: 45°C; water flow of cooling + heat recovery mode. 4. Water resistance at the air conditioner side includes water pressure drop of the unit and the attached Y-shaped filter. 5. Water resistance at the hot water side includes water pressure drop of the unit and does not include the pressure drop at the Y-shaped filter and other components. 6. Pipes outside the unit need to be customized and installed on site. The diameter of the pipes must meet design requirements. TILI does not provide the pipes. 7. Full heat recovery units and other units can be combined to form partial heat recovery modular system. Full heat recovery units can also be combined to form a total heat recovery system. Modular units can be formed using the 1~16 basic modules. The above table lists the parameters for common module combinations. 8. For on-site electric wiring, see the name plate or installation menu of the unit. |
Send your message to this supplier